Setpoint Ramp adjustment

<< Click to Display Table of Contents >>

Navigation:  Valve Firmware > Pressure Control > Adaptive algorithm > Tuning >

Setpoint Ramp adjustment

Previous pageReturn to chapter overviewNext page

Setpoint Ramp effects: Undershoot of pressure, Response time

 

This parameter defines the time that is used to decrease / raise pressure between 2 setpoints, particularly during pressure reduction, optimizing the setpoint ramp time can significantly enhance pressure response.

 

Pressure chart

PressureChart

Choose the applicable formula depending on units you are familiar with.

 

t = Setpoint Ramp

 

Adjustment procedure:

 

1.Start with optimal Gain Factor adjustment and Sensor Delay adjustment according to preceding tuning steps.

2.Control a typical pressure / flow situation.

3.Control a lower pressure.

4.Repeat from step 2 with longer setpoint ramps until best response is achieved.

5.Verify pressure control response for a setpoint raise situation.

 


Pfeil

In case a long ramp time is required to get optimal performance for pressure decrease situations it may be of advantage to apply different settings for decrease / raise control situations.