<< Click to Display Table of Contents >> Power Failure Option |
![]() ![]()
|
Power Failure option is circuit board that can store as much energy to close or open the valve in the event of a power failure.
Technical data
Charging Time |
2 minutes max. |
Durability |
Up to 10 years @ 25°C ambient |
These settings define what the valve is doing in case the power fails.
|
Valve must be equipped with the ‘Power Failure Option’ For PFO retrofit and other options refer to chapter: «Spare parts». |
Parameter |
Description |
Enable |
‘True’ enables the power fail reaction. ‘False’ there is no reaction on a power fail |
State |
0 Battery is Charging 1 Ready to Use 2 Active 3 Failure |
Functionality |
0 Open 1 Close |
Delay |
In seconds After this delay the power failure reaction starts after the power failed. Helps to bridge a short power interruption. |
Battery Voltage |
Shows state of charge |
Power Fail Cycles |
Counts Power Failure |
Location:
CPA Parameters |
Power Fail Option |