Parameter

<< Click to Display Table of Contents >>

Navigation:  »No topics above this level«

Parameter

Return to chapter overview

Parameter

Description

Analog Output Pressure

Value

Indicate the applied voltage

User Factor

1 default value for Input voltage 0 to 10V

UserFactor = ( MaxVolt – MinVolt ) / 10

 

Example: Input voltage 2V to 8V

(8-2)/10 = 0.6 User Factor.

User Offset

0 default value for Input voltage 0 to 10V

UserOffset = MinVolt

 

Example: Input voltage 2V to 8V

2.0 = User Offset