Functionality

<< Click to Display Table of Contents >>

Navigation:  Valve Firmware > Interface > Logic > Digital Outputs >

Functionality

Previous pageReturn to chapter overviewNext page

Functionality

Description

Open

Indicate the Open status of the Valve.

Close

Indicate the Close status of the Valve.

Busy

Busy is when:

Control Mode: Init, Homing, Learn, Power Failure, Error.

Control Mode: Pressure AND Actual Pressure is +/- 2% out of range.

Control Mode: Position AND Actual Position is +/- 0.1% out of range.

same ranges for Position and Pressure, if Hold will be active

Ready

Not Ready (0) when

Access Mode: Local

Control Mode: Init, Homing, Interlock Open, Interlock Close, Power Failure, Safety, Error

Table  Functionality Digital Outputs

 

IC Compatible Mode:

Busy

Busy is when:

Control Mode: Homing, Learn, Power Failure, Error.

Control Mode: Pressure AND Actual Pressure is +/- 2% out of range.

Control Mode: Position, Open, Interlock Open AND Actual Position is +/- 0.1% out of range

same ranges for Position and Pressure, if Hold will be active

Control Mode: Init, Close, Interlock Close AND valve is still not isolated

Ready

Not Ready (0) when

Access Mode: Local

Control Mode: Interlock Open, Interlock Close, Power Failure, Safety, Error

Control Mode: Init, Homing AND valve is not isolated

Table  Functionality Digital Outputs in IC Compatible Mode

 

-> If IC Compatible Mode is not visible, installed firmware does not provide this setting. Please check with VAT for firmware update.